PowerPod
Deploy Anywhere - Power Everything
Mobile microgrid in a box that integrates revolutionary graphene solar panels and supercapacitor energy storage to deliver safe, resilient power - engineered for military and humanitarian missions in remote, austere environments.





Container: 10 or 20ft Conex
Solar: 56-160 kWp
Storage: 600kWh - 1.2MWh Inputs: Grid/Gen/DER
Cost: Lowest Install Cost





Safe: No Li-Ion No Thermal Runaway
Scalable: Unlimited Linked Pods
Fast Deployment: 4 Hour Setup
Mobile: Retract, Close & Go
Warranty: 10 Years
Custom Configurations Available
10 Foot High Cube
CONTAINER
-
Type: 10 ft High Cube
-
Size: L:10ft × W:8ft × H:9.5ft
-
Deployed Footprint: 160ft L x 15.3ft (2450 ft2)
-
Total Weight: 13,500 lbs (6,137 kg)
PV SOLAR POWER
-
PV Solar Capacity: 80 kWp (80 Panels × 1000 Wp/Panel)
-
Typical Production: 336 kWh (700W per panel and 6 hrs of sun)
-
AC Output: 60 kW continuous
ENERGY STORAGE (DC INPUT/OUTPUT)
-
Nominal Voltage: 270 VDC
-
DC Voltage Range: 205 – 300 VDC
-
Battery Type: Graphene Supercapacitor
-
Battery Capacity: 600 kWh (Gen 9 Cells)
-
Min/Max Charge Voltage: 235 VDC / 297 VDC
-
Max Charge Current: 500 A @ 240 VDC
-
Max Discharge Current: 250 A
-
Max Charge Power: 120 kW (80 kW PV + 40 kW Grid/Gen)
-
Max Discharge Power: 60kW
AC INPUT (GRID/GENERATOR)
-
Voltage (L-L): 380 / 400 / 415 VAC
-
Voltage (L-N): 220 / 230 / 240 VAC
-
Phase: 3-phase 4 wires
-
Frequency: 50 / 60 Hz ± 2 Hz
-
Input Voltage: 360 – 480 VAC (L–L)
-
Max AC Input Current: 90 A @ 400 VAC
-
ATS Base Connections: 1×125 A Breaker (Grid), 2×125 A Breakers (2xGenerator), Optional CEE Plugs
AC OUTPUT
-
Voltage (L-L): 380 / 400 / 415 VAC
-
Voltage (L-N): 220 / 230 / 240 VAC
-
Phase: 3-phase 4 wires
-
Frequency: 50 / 60 Hz
-
Waveform: Pure Sine Wave
-
Nominal Output Current: 90 A @ 400 VAC
-
Max Output Current: 500 A @ 400 VAC
-
Power Factor: 0.99
-
Total Harmonic Distortion: THDi < 3%
-
Max Surge Current: 200%
-
Output Connections: 1×125 A Breaker @ 3 Phase 400 Vac (Optional distribution panel with ground fault, breakers and CEE Plugs 1×50 A 3 Phase and 6×16 A Single Phase)
SYSTEM
-
Operating Modes: On-Grid/Off-Grid Mode (Automatic island mode with built-in ATS), Microgrid Mode (Parallel up to 10 containers)
-
Peak Efficiency: >95%
-
Power Consumption: Standby Mode: 60 W, Idle Mode: 520 W
-
Standby to Idle Mode: 3 second reaction time
-
Idle to Full Power: 12 milliseconds
-
LCD Display: Shows Inverter (V/A/Hz/W), AC input (V/A/Hz/W), Battery (V/A/SOC %), Accumulated energy data, System status, Time, Date, Heat sink temperature, Data log and Event log
-
Communication Port: Local RS-485 and RJ45
-
Protocol: CANBUS, MODBUS
-
Temperature: -20°C to 50°C (Power draining above 60 °C)
-
Maximum Altitude: 12,000 ft
-
Design Standards: IEC 61727, IEC 62116, IEC 62109-1, IEC 62109-2, UN38.3, TF331
-
Ingress Protection: IP 65
-
Protective Class: I



10 Foot Standard Cube
CONTAINER
-
Type: 10 ft Standard Cube
-
Size: 10 ft L × 8 ft W × 8.5 ft H
-
Deployed Footprint: 150 ft x 15 ft (2250 ft²)
-
Total Weight: 13,000 lbs (5910kg)
PV SOLAR POWER
-
PV Solar Capacity: 56 kWp (80 Panels x 700 Wp per Panel)
-
Typical Production: 252 kWh (525W per panel and 6 hrs of sun)
-
AC Output: 60 kW continuous
ENERGY STORAGE (DC INPUT/OUTPUT)
-
Nominal Voltage: 270 VDC
-
DC Voltage Range: 205 – 300 VDC
-
Battery Type: Graphene Supercapacitor
-
Battery Capacity: 600 kWh (Gen 9 Cells)
-
Min/Max Charge Voltage: 235 VDC / 297 VDC
-
Max Charge Current: 500 A @ 240 VDC
-
Max Discharge Current: 250 A
-
Max Charge Power: 120 kW (80 kW PV + 40 kW Grid/Gen)
-
Max Discharge Power: 60kW
AC INPUT (GRID/GENERATOR)
-
Voltage (L-L): 380 / 400 / 415 VAC
-
Voltage (L-N): 220 / 230 / 240 VAC
-
Phase: 3-phase 4 wires
-
Frequency: 50 / 60 Hz ± 2 Hz
-
Input Voltage: 360 – 480 VAC (L–L)
-
Max AC Input Current: 90 A @ 400 VAC
-
ATS Base Connections: 1×125 A Breaker (Grid), 2×125 A Breakers (2×Generator), Optional CEE Plug
AC OUTPUT
-
Voltage (L-L): 380 / 400 / 415 VAC
-
Voltage (L-N): 220 / 230 / 240 VAC
-
Phase: 3-phase 4 wires
-
Frequency: 50 / 60 Hz
-
Waveform: Pure Sine Wave
-
Nominal Output Current: 90 A @ 400 VAC
-
Max Output Current: 500 A @ 400 VAC
-
Power Factor: 0.99
-
Total Harmonic Distortion: THDi < 3%
-
Max Surge Current: 200%
-
Output Connections: 1×125 A Breaker @ 3 Phase 400 Vac (Optional distribution panel with ground fault, breakers and CEE Plugs 1×50 A 3 Phase and 6×16 A Single Phase)
SYSTEM
-
Operating Modes: On-Grid/Off-Grid Mode (Automatic island mode with built-in ATS), Microgrid Mode (Parallel up to 10 containers)
-
Peak Efficiency: >95%
-
Power Consumption: Standby Mode: 60 W, Idle Mode: 520 W
-
Standby to Idle Mode: 3 second reaction time
-
Idle to Full Power: 12 milliseconds
-
LCD Display: Shows Inverter (V/A/Hz/W), AC input (V/A/Hz/W), Battery (V/A/SOC %), Accumulated energy data, System status, Time, Date, Heat sink temperature, Data log and Event log
-
Communication Port: Local RS-485 and RJ45
-
Protocol: CANBUS and MODBUS
-
Temperature: -20°C to 50°C (Power draining above 60 °C)
-
Maximum Altitude: 12,000 ft
-
Design Standards: IEC 61727, IEC 62116, IEC 62109-1, IEC 62109-2, UN38.3, TF331
-
Ingress Protection: IP 65
-
Protective Class: I




20 Foot High Cube
CONTAINER
-
Type: 20 ft High Cube
-
Size: 20 ft L × 8 ft W × 9.5 ft H
-
Deployed Footprint: 320 ft X 15.3 ft (4896 ft²)
-
Total Weight: 26,000 lbs (11,818 kg)
PV SOLAR POWER
-
PV Solar Capacity: 160 kWp(160 Panels x 1000 Wp per Panel)
-
Typical Production: 672 kWh (700W per panel and 6 hrs of sun)
-
Energy Density: 335 W/m²
-
AC Output: 60 kW continuous
ENERGY STORAGE (DC INPUT/OUTPUT)
-
Nominal Voltage: 270 VDC
-
DC Voltage Range: 205 – 300 VDC
-
Battery Type: Graphene Supercapacitor
-
Battery Capacity: 1.2 MWh (Gen 9 Cells)
-
Min/Max Charge Voltage: 235 VDC / 297 VDC
-
Max Charge Current: 500 A @ 240 VDC
-
Max Discharge Current: 250 A
-
Max Charge Power: 120 kW (80 kW PV + 40 kW Grid/Gen)
-
Max Discharge Power: 60kW
AC INPUT (GRID/GENERATOR)
-
Voltage (L-L): 380 / 400 / 415 VAC
-
Voltage (L-N): 220 / 230 / 240 VAC
-
Phase: 3-phase 4 wires
-
Frequency: 50 / 60 Hz ± 2 Hz
-
Input Voltage: 360 – 480 VAC (L–L)
-
Max AC Input Current: 90 A @ 400 VAC
-
ATS Base Connections: 1×125 A Breaker (Grid), 2×125 A Breakers (2×Generator), Optional CEE Plug
AC OUTPUT
-
Voltage (L-L): 380 / 400 / 415 VAC
-
Voltage (L-N): 220 / 230 / 240 VAC
-
Phase: 3-phase 4 wires
-
Frequency: 50 / 60 Hz
-
Waveform: Pure Sine Wave
-
Nominal Output Current: 90 A @ 400 VAC
-
Max Output Current: 500 A @ 400 VAC
-
Power Factor: 0.99
-
Total Harmonic Distortion: THDi < 3%
-
Max Surge Current: 200%
-
Output Connections: 1×125 A Breaker @ 3 Phase 400 Vac (Optional distribution panel with ground fault, breakers and CEE Plugs 1×50 A 3 Phase and 6×16 A Single Phase)
SYSTEM
-
Operating Modes: On-Grid/Off-Grid Mode (Automatic island mode with built-in ATS), Microgrid Mode (Parallel up to 10 containers)
-
Peak Efficiency: >95%
-
Power Consumption: Standby Mode: 60 W, Idle Mode: 520 W
-
Standby to Idle Mode: 3 second reaction time
-
Idle to Full Power: 12 milliseconds
-
LCD Display: Shows Inverter (V/A/Hz/W), AC input (V/A/Hz/W), Battery (V/A/SOC %), Accumulated energy data, System status, Time, Date, Heat sink temperature, Data log and Event log
-
Communication Port: Local RS-485 and RJ45
-
Protocol: CANBUS and MODBUS
-
Temperature: -20°C to 50°C (Power draining above 60 °C)
-
Maximum Altitude: 12,000 ft
-
Design Standards: IEC 61727, IEC 62116, IEC 62109-1, IEC 62109-2, UN38.3, TF331
-
Ingress Protection: IP 65
-
Protective Class: I




20 Foot Standard Cube
CONTAINER
-
Type: 20 ft Standard Cube
-
Size: 20 ft L × 8 ft W × 8.5 ft H
-
Deployed Footprint: 300ft × 15 ft (4500 ft²)
-
Total Weight: 23,500 lbs (10,680 kg)
PV SOLAR POWER
-
PV Solar Capacity: 112 kWp (160 Panels × 700 Wp per Panel)
-
Typical Production: 504 kW (525 W per panel and 6 hrs of sun)
-
Energy Density: 335 W/m²
-
AC Output: 60 kW continuous
ENERGY STORAGE (DC INPUT/OUTPUT)
-
Nominal Voltage: 270 VDC
-
DC Voltage Range: 205 – 300 VDC
-
Battery Type: Graphene Supercapacitor
-
Battery Capacity: 1.2 MWh (Gen 9 Cells)
-
Min/Max Charge Voltage: 235 VDC / 297 VDC
-
Max Charge Current: 500 A @ 240 VDC
-
Max Discharge Current: 250 A
-
Max Charge Power: 152 kW (112 kW PV + 40 kW Grid/Gen)
-
Max Discharge Power: 60kW
AC INPUT (GRID/GENERATOR)
-
Voltage (L-L): 380 / 400 / 415 VAC
-
Voltage (L-N): 220 / 230 / 240 VAC
-
Phase: 3-phase 4 wires
-
Frequency: 50 / 60 Hz ± 2 Hz
-
Input Voltage: 360 – 480 VAC (L–L)
-
Max AC Input Current: 90 A @ 400 VAC
-
ATS Base Connections: 1×125 A Breaker (Grid), 2×125 A Breakers (2×Generator), Optional CEE Plug Voltage (L-L): 380 / 400 / 415 VA
AC OUTPUT
-
Voltage (L-L): 380 / 400 / 415 VAC
-
Voltage (L-N): 220 / 230 / 240 VAC
-
Phase: 3-phase 4 wires
-
Frequency: 50 / 60 Hz
-
Waveform: Pure Sine Wave
-
Nominal Output Current: 90 A @ 400 VAC
-
Max Output Current: 500 A @ 400 VAC
-
Power Factor: 0.99
-
Total Harmonic Distortion: THDi < 3%
-
Max Surge Current: 200%
-
Output Connections: 1×125 A Breaker @ 3 Phase 400 Vac (Optional distribution panel with ground fault, breakers and CEE Plugs 1×50 A 3 Phase and 6×16 A Single Phase)
SYSTEM
-
Operating Modes: On-Grid/Off-Grid Mode (Automatic island mode with built-in ATS), Microgrid Mode (Parallel up to 10 containers)
-
Peak Efficiency: >95%
-
Power Consumption: Standby Mode: 60 W, Idle Mode: 520 W
-
Standby to Idle Mode: 3 second reaction time
-
Idle to Full Power: 12 milliseconds
-
LCD Display: Shows Inverter (V/A/Hz/W), AC input (V/A/Hz/W), Battery (V/A/SOC %), Accumulated energy data, System status, Time, Date, Heat sink temperature, Data log and Event log
-
Communication Port: Local RS-485 and RJ45
-
Protocol: CANBUS and MODBUS
-
Temperature: -20°C to 50°C (Power draining above 60 °C)
-
Maximum Altitude: 12,000 ft
-
Design Standards: IEC 61727, IEC 62116, IEC 62109-1, IEC 62109-2, UN38.3, TF331
-
Ingress Protection: IP 65
-
Protective Class: I