top of page

PowerPod 

Deploy Anywhere - Power Everything 

Mobile microgrid in a box that integrates revolutionary graphene solar panels and supercapacitor energy storage to deliver safe, resilient power - engineered for military and humanitarian missions in remote, austere environments.

Icon-Shipping Container.png
Image_edited.png
Image_edited.png
f90d2c32-b2b7-4706-9453-5ccc69f64a7b_edi

Container: 10 or 20ft Conex

Solar: 56-160 kWp 

Storage: 600kWh - 1.2MWh Inputs: Grid/Gen/DER

Cost: Lowest Install Cost

Image_edited_edited.png
Image_edited_edited.png
f90d2c32-b2b7-4706-9453-5ccc69f64a7b_edi
f90d2c32-b2b7-4706-9453-5ccc69f64a7b_edi

Safe: No Li-Ion No Thermal Runaway

Scalable: Unlimited Linked Pods

Fast Deployment: 4 Hour Setup

Mobile: Retract, Close & Go

Warranty: 10 Years

Custom Configurations Available

10 Foot High Cube

CONTAINER

  • Type: 10 ft High Cube

  • Size: L:10ft × W:8ft × H:9.5ft

  • Deployed Footprint: 160ft L x 15.3ft (2450 ft2)

  • Total Weight: 13,500 lbs (6,137 kg)

PV SOLAR POWER

  • PV Solar Capacity: 80 kWp (80 Panels × 1000 Wp/Panel)

  • Typical Production: 336 kWh (700W per panel and 6 hrs of sun)

  • AC Output: 60 kW continuous

ENERGY STORAGE (DC INPUT/OUTPUT)

  • Nominal Voltage: 270 VDC

  • DC Voltage Range: 205 – 300 VDC

  • Battery Type: Graphene Supercapacitor 

  • Battery Capacity: 600 kWh (Gen 9 Cells)

  • Min/Max Charge Voltage: 235 VDC / 297 VDC

  • Max Charge Current: 500 A @ 240 VDC

  • Max Discharge Current: 250 A

  • Max Charge Power: 120 kW (80 kW PV + 40 kW Grid/Gen)

  • Max Discharge Power: 60kW

 

AC INPUT (GRID/GENERATOR)

  • Voltage (L-L): 380 / 400 / 415 VAC

  • Voltage (L-N): 220 / 230 / 240 VAC

  • Phase: 3-phase 4 wires

  • Frequency: 50 / 60 Hz ± 2 Hz

  • Input Voltage: 360 – 480 VAC (L–L)

  • Max AC Input Current: 90 A @ 400 VAC

  • ATS Base Connections: 1×125 A Breaker (Grid), 2×125 A Breakers (2xGenerator), Optional CEE Plugs

AC OUTPUT

  • Voltage (L-L): 380 / 400 / 415 VAC 

  • Voltage (L-N): 220 / 230 / 240 VAC

  • Phase: 3-phase 4 wires

  • Frequency: 50 / 60 Hz

  • Waveform: Pure Sine Wave

  • Nominal Output Current: 90 A @ 400 VAC

  • Max Output Current: 500 A @ 400 VAC 

  • Power Factor: 0.99

  • Total Harmonic Distortion: THDi < 3%

  • Max Surge Current: 200%

  • Output Connections: 1×125 A Breaker @ 3 Phase 400 Vac (Optional distribution panel with ground fault, breakers and CEE Plugs 1×50 A 3 Phase and 6×16 A Single Phase)

SYSTEM

  • Operating Modes: On-Grid/Off-Grid Mode (Automatic island mode with built-in ATS), Microgrid Mode (Parallel up to 10 containers) 

  • Peak Efficiency: >95%

  • Power Consumption: Standby Mode: 60 W, Idle Mode: 520 W

  • Standby to Idle Mode: 3 second reaction time

  • Idle to Full Power: 12 milliseconds

  • LCD Display: Shows Inverter (V/A/Hz/W), AC input (V/A/Hz/W), Battery (V/A/SOC %), Accumulated energy data, System status, Time, Date, Heat sink temperature, Data log and Event log

  • Communication Port: Local RS-485 and RJ45

  • Protocol: CANBUS, MODBUS

  • Temperature: -20°C to 50°C (Power draining above 60 °C)

  • Maximum Altitude: 12,000 ft 

  • Design Standards: IEC 61727, IEC 62116, IEC 62109-1, IEC 62109-2, UN38.3, TF331

  • Ingress Protection: IP 65

  • Protective Class: I

10 Foot Standard Cube

CONTAINER

  • Type: 10 ft Standard Cube

  • Size: 10 ft L × 8 ft W × 8.5 ft H

  • Deployed Footprint: 150 ft x 15 ft (2250 ft²)

  • Total Weight: 13,000 lbs (5910kg)

PV SOLAR POWER

  • PV Solar Capacity: 56 kWp (80 Panels x 700 Wp per Panel)

  • Typical Production: 252 kWh (525W per panel and 6 hrs of sun)

  • AC Output: 60 kW continuous

ENERGY STORAGE (DC INPUT/OUTPUT)

  • Nominal Voltage: 270 VDC

  • DC Voltage Range: 205 – 300 VDC

  • Battery Type: Graphene Supercapacitor 

  • Battery Capacity: 600 kWh (Gen 9 Cells)

  • Min/Max Charge Voltage: 235 VDC / 297 VDC

  • Max Charge Current: 500 A @ 240 VDC

  • Max Discharge Current: 250 A

  • Max Charge Power: 120 kW (80 kW PV + 40 kW Grid/Gen)

  • Max Discharge Power: 60kW

AC INPUT (GRID/GENERATOR)

  • Voltage (L-L): 380 / 400 / 415 VAC

  • Voltage (L-N): 220 / 230 / 240 VAC

  • Phase: 3-phase 4 wires

  • Frequency: 50 / 60 Hz ± 2 Hz

  • Input Voltage: 360 – 480 VAC (L–L)

  • Max AC Input Current: 90 A @ 400 VAC

  • ATS Base Connections: 1×125 A Breaker (Grid), 2×125 A Breakers (2×Generator), Optional CEE Plug 

 

AC OUTPUT

  • Voltage (L-L): 380 / 400 / 415 VAC

  • Voltage (L-N): 220 / 230 / 240 VAC

  • Phase: 3-phase 4 wires

  • Frequency: 50 / 60 Hz

  • Waveform: Pure Sine Wave

  • Nominal Output Current: 90 A @ 400 VAC

  • Max Output Current: 500 A @ 400 VAC 

  • Power Factor: 0.99

  • Total Harmonic Distortion: THDi < 3%

  • Max Surge Current: 200%

  • Output Connections: 1×125 A Breaker @ 3 Phase 400 Vac (Optional distribution panel with ground fault, breakers and CEE Plugs 1×50 A 3 Phase and 6×16 A Single Phase)

SYSTEM

  • Operating Modes: On-Grid/Off-Grid Mode (Automatic island mode with built-in ATS), Microgrid Mode (Parallel up to 10 containers) 

  • Peak Efficiency: >95%

  • Power Consumption: Standby Mode: 60 W, Idle Mode: 520 W

  • Standby to Idle Mode: 3 second reaction time

  • Idle to Full Power: 12 milliseconds

  • LCD Display: Shows Inverter (V/A/Hz/W), AC input (V/A/Hz/W), Battery (V/A/SOC %), Accumulated energy data, System status, Time, Date, Heat sink temperature, Data log and Event log

  • Communication Port: Local RS-485 and RJ45 

  • Protocol: CANBUS and MODBUS

  • Temperature: -20°C to 50°C (Power draining above 60 °C)

  • Maximum Altitude: 12,000 ft 

  • Design Standards: IEC 61727, IEC 62116, IEC 62109-1, IEC 62109-2, UN38.3, TF331

  • Ingress Protection: IP 65

  • Protective Class: I

20 Foot High Cube

CONTAINER

  • Type: 20 ft High Cube

  • Size: 20 ft L × 8 ft W × 9.5 ft H

  • Deployed Footprint: 320 ft X 15.3 ft (4896 ft²)

  • Total Weight: 26,000 lbs (11,818 kg)

PV SOLAR POWER

  • PV Solar Capacity: 160 kWp(160 Panels x 1000 Wp per Panel)

  • Typical Production: 672 kWh (700W per panel and 6 hrs of sun)

  • Energy Density: 335 W/m²

  • AC Output: 60 kW continuous

ENERGY STORAGE (DC INPUT/OUTPUT)

  • Nominal Voltage: 270 VDC

  • DC Voltage Range: 205 – 300 VDC

  • Battery Type: Graphene Supercapacitor 

  • Battery Capacity: 1.2 MWh (Gen 9 Cells)

  • Min/Max Charge Voltage: 235 VDC / 297 VDC

  • Max Charge Current: 500 A @ 240 VDC

  • Max Discharge Current: 250 A

  • Max Charge Power: 120 kW (80 kW PV + 40 kW Grid/Gen)

  • Max Discharge Power: 60kW

AC INPUT (GRID/GENERATOR)

  • Voltage (L-L): 380 / 400 / 415 VAC

  • Voltage (L-N): 220 / 230 / 240 VAC

  • Phase: 3-phase 4 wires

  • Frequency: 50 / 60 Hz ± 2 Hz

  • Input Voltage: 360 – 480 VAC (L–L)

  • Max AC Input Current: 90 A @ 400 VAC

  • ATS Base Connections: 1×125 A Breaker (Grid), 2×125 A Breakers (2×Generator), Optional CEE Plug 

 

AC OUTPUT

  • Voltage (L-L): 380 / 400 / 415 VAC

  • Voltage (L-N): 220 / 230 / 240 VAC

  • Phase: 3-phase 4 wires

  • Frequency: 50 / 60 Hz

  • Waveform: Pure Sine Wave

  • Nominal Output Current: 90 A @ 400 VAC

  • Max Output Current: 500 A @ 400 VAC 

  • Power Factor: 0.99

  • Total Harmonic Distortion: THDi < 3%

  • Max Surge Current: 200%

  • Output Connections: 1×125 A Breaker @ 3 Phase 400 Vac (Optional distribution panel with ground fault, breakers and CEE Plugs 1×50 A 3 Phase and 6×16 A Single Phase)

SYSTEM

  • Operating Modes: On-Grid/Off-Grid Mode (Automatic island mode with built-in ATS), Microgrid Mode (Parallel up to 10 containers) 

  • Peak Efficiency: >95%

  • Power Consumption: Standby Mode: 60 W, Idle Mode: 520 W

  • Standby to Idle Mode: 3 second reaction time

  • Idle to Full Power: 12 milliseconds

  • LCD Display: Shows Inverter (V/A/Hz/W), AC input (V/A/Hz/W), Battery (V/A/SOC %), Accumulated energy data, System status, Time, Date, Heat sink temperature, Data log and Event log 

  • Communication Port: Local RS-485 and RJ45 

  • Protocol: CANBUS and MODBUS

  • Temperature: -20°C to 50°C (Power draining above 60 °C)

  • Maximum Altitude: 12,000 ft 

  • Design Standards: IEC 61727, IEC 62116, IEC 62109-1, IEC 62109-2, UN38.3, TF331

  • Ingress Protection: IP 65

  • Protective Class: I

20 Foot Standard Cube

CONTAINER

  • Type: 20 ft Standard Cube

  • Size: 20 ft L × 8 ft W × 8.5 ft H

  • Deployed Footprint: 300ft × 15 ft (4500 ft²)

  • Total Weight: 23,500 lbs (10,680 kg)

PV SOLAR POWER

  • PV Solar Capacity: 112 kWp (160 Panels × 700 Wp per Panel)

  • Typical Production: 504 kW (525 W per panel and 6 hrs of sun)

  • Energy Density: 335 W/m²

  • AC Output: 60 kW continuous

ENERGY STORAGE (DC INPUT/OUTPUT)

  • Nominal Voltage: 270 VDC

  • DC Voltage Range: 205 – 300 VDC

  • Battery Type: Graphene Supercapacitor 

  • Battery Capacity: 1.2 MWh (Gen 9 Cells)

  • Min/Max Charge Voltage: 235 VDC / 297 VDC

  • Max Charge Current: 500 A @ 240 VDC

  • Max Discharge Current: 250 A

  • Max Charge Power: 152 kW (112 kW PV + 40 kW Grid/Gen)

  • Max Discharge Power: 60kW

AC INPUT (GRID/GENERATOR)

  • Voltage (L-L): 380 / 400 / 415 VAC

  • Voltage (L-N): 220 / 230 / 240 VAC

  • Phase: 3-phase 4 wires

  • Frequency: 50 / 60 Hz ± 2 Hz

  • Input Voltage: 360 – 480 VAC (L–L)

  • Max AC Input Current: 90 A @ 400 VAC

  • ATS Base Connections: 1×125 A Breaker (Grid), 2×125 A Breakers (2×Generator), Optional CEE Plug   Voltage (L-L): 380 / 400 / 415 VA

AC OUTPUT

  • Voltage (L-L): 380 / 400 / 415 VAC

  • Voltage (L-N): 220 / 230 / 240 VAC

  • Phase: 3-phase 4 wires

  • Frequency: 50 / 60 Hz

  • Waveform: Pure Sine Wave

  • Nominal Output Current: 90 A @ 400 VAC

  • Max Output Current: 500 A @ 400 VAC 

  • Power Factor: 0.99

  • Total Harmonic Distortion: THDi < 3%

  • Max Surge Current: 200%

  • Output Connections: 1×125 A Breaker @ 3 Phase 400 Vac (Optional distribution panel with ground fault, breakers and CEE Plugs 1×50 A 3 Phase and 6×16 A Single Phase)

SYSTEM

  • Operating Modes: On-Grid/Off-Grid Mode (Automatic island mode with built-in ATS), Microgrid Mode (Parallel up to 10 containers) 

  • Peak Efficiency: >95%

  • Power Consumption: Standby Mode: 60 W, Idle Mode: 520 W

  • Standby to Idle Mode: 3 second reaction time

  • Idle to Full Power: 12 milliseconds

  • LCD Display: Shows Inverter (V/A/Hz/W), AC input (V/A/Hz/W), Battery (V/A/SOC %), Accumulated energy data, System status, Time, Date, Heat sink temperature, Data log and Event log

  • Communication Port: Local RS-485 and RJ45 

  • Protocol: CANBUS and MODBUS

  • Temperature: -20°C to 50°C (Power draining above 60 °C)

  • Maximum Altitude: 12,000 ft 

  • Design Standards: IEC 61727, IEC 62116, IEC 62109-1, IEC 62109-2, UN38.3, TF331

  • Ingress Protection: IP 65

  • Protective Class: I

bottom of page